Reed Instruments R5850-NIST Multi-Function Process Calibrator
- ✓ Free Shipping US Wide
- ✓ Need Help? Call Us At (888) 913-3691
- ✓ Get The Best Price. Call Us
- ✓ 30 Day Returns
The REED Instruments R5850-NIST is a high-accuracy, handheld solution for the calibration and troubleshooting of process control instrumentation.
Designed for versatility, the R5850 can both source (simulate) and measure a wide range of signals, including DC voltage, DC current (mA), 12 thermocouple types (R, S, B, E, K, J, T, N, L, U, XK, BP), and 10 RTD types (Pt100, Pt200, Pt500, Pt1000, Cu10/50/100, Pt100-392, Pt100-JIS, Ni120). With the included NIST-Traceable Calibration Certificate, this tool provides the documented measurement integrity required for chemical plants, water treatment facilities, and pharmaceutical manufacturing.
Comprehensive Source/Measure Capability: Eliminate the need for multiple tools by simulating and measuring 0-10V DC and 0-22mA DC signals in a single device.
Universal Temperature Calibration: Supports the most common industrial sensors, including R, S, B, E, K, J, T, N, L, U, XK and BP thermocouples, as well as Pt100, Pt200, Pt500, Pt1000, Cu10/50/100, Pt100-392, Pt100-JIS and Ni120 RTDs.
Integrated 24V Loop Power: Power and test 2-wire loops simultaneously, making it an all-in-one solution for transmitter maintenance.
Documented Accuracy: Ships with a NIST-traceable certificate containing full data and uncertainties, ensuring compliance with ISO and regulatory safety standards.
Field-Ready Design: Features an easy-to-read backlit LCD, internal memory for storing calibration set-points, and a rugged housing built for industrial environments.
Industrial Transmitter Calibration: Verify and adjust 4-20mA pressure, flow, and level transmitters.
HVAC/R Control Systems: Test and simulate temperature sensors (RTDs/Thermocouples) for large-scale climate control.
PLC and DCS Troubleshooting: Inject known signals into control systems to verify programming logic and I/O performance.
Chemical & Water Treatment: Maintain precise sensor accuracy in environments where chemical dosing depends on exact measurements.
Pharmaceutical & Food Processing: Ensure thermal monitoring equipment meets strict FDA and health safety compliance through traceable calibration.
| DC Voltage | |
| Range | 50, 500mV, 30V (upper display), 50V (lower display) |
| Resolution | 0.001, 0.01, 1mV, 0.001V |
| Accuracy | 50mV: ±(0.02% +10) / 500mV: ±(0.02% +5) |
| 30V (upper display): ±(0.02% +2) / 50V (lower display): ±(0.02% +2) |
| DC Current | |
| Range | 20mA at 0 to 24mA |
| Resolution | 0.001mA |
| Accuracy | ±(0.02% +2) |
| Loop Current | |
| Range | 20mA (loop) at 0 to 24mA |
| Resolution | 0.001mA |
| Accuracy | ±(0.02% +2) |
| Resistance | |
| Range | 500, 5000Ω |
| Resolution | 0.01, 0.1Ω |
| Accuracy | ±(0.05% +10) |
| Frequency | |
| Range | 100Hz, 1, 10, 100kHz |
| Resolution | 0.01, 0.1, 1Hz |
| Accuracy | ±(0.01% +1) |
| Type R and Type S | |
| Range | 32 to 3212.6°F (0 to 1767°C) |
| Resolution | 1°F/°C |
| Accuracy | 32 to 932°F (0 to 500°C): ±3.24°F (±1.8°C) |
| 932 to 3212.6°F (500 to 1767°C): ±2.7°F (±1.5°C) |
| Type B | |
| Range | 1112 to 3308°F (600 to 1820°C) |
| Resolution | 1°F/°C |
| Accuracy | 1112 to 1472°F (600 to 800°C): ±3.96°F (±2.2°C) |
| 1472 to 1832°F (800 to 1000°C): ±3.24°F (±1.8°C) | |
| 1832 to 3308°F (1000 to 1820°C): ±2.52°F (±1.4°C) |
| Type E | |
| Range | -58 to 1832°F (-50 to 1000°C) |
| Resolution | 0.1°F/°C |
| Accuracy | -58 to 32°F (-50 to 0°C): ±1.62°F (±0.9°C) |
| 32 to 1832°F (0 to 1000°C): ±2.7°F (±1.5°C) |
| Type K | |
| Range | -148 to 2501.6°F (-100 to 1372°C) |
| Resolution | 0.1°F/°C |
| Accuracy | -148 to 32°F (-100 to 0°C): ±2.16°F (±1.2°C) |
| 32 to 2501.6°F (0 to 1372°C): ±1.44°F (±0.8°C) |
| Type J | |
| Range | -76 to 2192°F (-60 to 1200°C) |
| Resolution | 0.1°F/°C |
| Accuracy | -76 to 32°F (-60 to 0°C): ±1.8°F (±1°C) |
| 32 to 2192°F (0 to 1200°C): ±1.26°F (±0.7°C) |
| Type T | |
| Range | -148 to 752°F (-100 to 400°C) |
| Resolution | 0.1°F/°C |
| Accuracy | -148 to 32°F (-100 to 0°C): ±1.8°F (±1°C) |
| 32 to 752°F (0 to 400°C): ±1.26°F (±0.7°C) |
| Type N | |
| Range | -328 to 2372°F (-200 to 1300°C) |
| Resolution | 0.1°F/°C |
| Accuracy | -328 to -148°F (-200 to -100°C): ±1.8°F (±1°C) |
| -148 to 1652°F (-100 to 900°C): ±1.26°F (±0.7°C) | |
| 1652 to 2372°F (900 to 1300°C): ±1.44°F (±0.8°C) |
| Type L | |
| Range | -328 to 1652°F (-200 to 900°C) |
| Resolution | 0.1°F/°C |
| Accuracy | -328 to 32°F (-200 to 0°C): ±1.53°F (±0.85°C) |
| 32 to 1652°F (0 to 900°C): ±1.26°F (±0.7°C) |
| Type U | |
| Range | -328 to 752°F (-200 to 400°C) |
| Resolution | 0.1°F/°C |
| Accuracy | -328 to 32°F (-200 to 0°C): ±1.98°F (±1.1°C) |
| 32 to 752°F (0 to 400°C): ±1.35°F (±0.75°C) |
| Type XK | |
| Range | -328 to 1472°F (-200 to 800°C) |
| Resolution | 0.1°F/°C |
| Accuracy | -328 to -148°F (-200 to -100°C): ±0.9°F (±0.5°C) |
| -148 to 1472°F (-100 to 800°C): ±1.08°F (±0.6°C) |
| Type BP | |
| Range | 32 to 4532°F (0 to 2500°C) |
| Resolution | 0.1°F/°C |
| Accuracy | 32 to 1472°F (0 to 800°C): ±2.16°F (±1.2°C) |
| 1472 to 4532°F (800 to 2500°C): ±4.5°F (±2.5°C) |
| Pt100 (2-wire/3-wire) | |
| Range | -328 to 1562°F (-200 to 850°C) |
| Resolution | 0.1°F/°C |
| Accuracy | ±0.72°F (±0.4°C) |
| Pt100 (4-wire) | |
| Range | -328 to 1562°F (-200 to 850°C) |
| Resolution | 0.1°F/°C |
| Accuracy | ±0.54°F (±0.3°C) |
| Pt200 (2-wire/3-wire) | |
| Range | -328 to 1166°F (-200 to 630°C) |
| Resolution | 0.1°F/°C |
| Accuracy | -328 to 482°F (-200 to 250°C): ±0.54°F (±0.3°C) |
| 482 to 1166°F (250 to 630°C): ±2.88°F (±1.6°C) |
| Pt200 (4-wire) | |
| Range | -328 to 1166°F (-200 to 630°C) |
| Resolution | 0.1°F/°C |
| Accuracy | -328 to 482°F (-200 to 250°C): ±0.36°F (±0.2°C) |
| 482 to 1166°F (250 to 630°C): ±1.44°F (±0.8°C) | |
| Pt500 (2-wire/3-wire) | |
| Range | -328 to 1166°F (-200 to 630°C) |
| Resolution | 0.1°F/°C |
| Accuracy | -328 to 932°F (-200 to 500°C): ±1.08°F (±0.6°C) |
| 932 to 1166°F (500 to 630°C): ±1.62°F (±0.9°C) | |
| Pt500 (4-wire) | |
| Range | -328 to 1166°F (-200 to 630°C) |
| Resolution | 0.1°F/°C |
| Accuracy | -328 to 932°F (-200 to 500°C): ±0.54°F (±0.3°C) |
| 932 to 1166°F (500 to 630°C): ±0.72°F (±0.4°C) |
| Pt1000 (2-wire/3-wire) | |
| Range | -328 to 1202°F (-200 to 650°C) |
| Resolution | 0.1°F/°C |
| Accuracy | ±0.54°F (±0.3°C) |
| Pt1000 (4-wire) | |
| Range | -328 to 1202°F (-200 to 650°C) |
| Resolution | 0.1°F/°C |
| Accuracy | ±0.27°F (±0.15°C) |
| Cu10 | |
| Range | -148 to 500°F (-100 to 260°C) |
| Resolution | 0.1°F/°C |
| Accuracy | ±3.24°F (±1.8°C) |
| Cu50 (2-wire/3-wire) | |
| Range | -58 to 302°F (-50 to 150°C) |
| Resolution | 0.1°F/°C |
| Accuracy | ±1.44°F (±0.8°C) |
| Cu50 (4-wire) | |
| Range | -58 to 302°F (-50 to 150°C) |
| Resolution | 0.1°F/°C |
| Accuracy | ±0.9°F (±0.5°C) |
| Cu100 (2-wire/3-wire) | |
| Range | -58 to 302°F (-50 to 150°C) |
| Resolution | 0.1°F/°C |
| Accuracy | ±0.72°F (±0.4°C) |
| Cu100 (4-wire) | |
| Range | -58 to 302°F (-50 to 150°C) |
| Resolution | 0.1°F/°C |
| Accuracy | ±0.45°F (±0.25°C) |
| Pt100-392 (2-wire/3-wire) | |
| Range | -328 to 1166°F (-200 to 630°C) |
| Resolution | 0.1°F/°C |
| Accuracy | ±0.9°F (±0.5°C) |
| Pt100-392 (4-wire) | |
| Range | -328 to 1166°F (-200 to 630°C) |
| Resolution | 0.1°F/°C |
| Accuracy | ±0.54°F (±0.3°C) |
| Pt100-JIS (2-wire/3-wire) | |
| Range | -328 to 1166°F (-200 to 630°C) |
| Resolution | 0.1°F/°C |
| Accuracy | ±0.9°F (±0.5°C) |
| Pt100-JIS (4-wire) | |
| Range | -328 to 1166°F (-200 to 630°C) |
| Resolution | 0.1°F/°C |
| Accuracy | ±0.54°F (±0.3°C) |
| Ni120 (2-wire/3-wire) | |
| Range | -112 to 500°F (-80 to 260°C) |
| Resolution | 0.1°F/°C |
| Accuracy | ±0.54°F (±0.3°C) |
| Ni120 (4-wire) | |
| Range | -112 to 500°F (-80 to 260°C) |
| Resolution | 0.1°F/°C |
| Accuracy | ±0.36°F (±0.2°C) |
| DC Voltage | |
| Range | 100mV, 1, 10V |
| Resolution | 0.001, 0.01mV, 0.0001V |
| Accuracy | ±(0.02% +10) |
| DC Current | |
| Range | 20mA at 0 to 24mA / 20mA (SIM) at 0 to 24mA |
| Resolution | 0.001mA |
| Accuracy | ±(0.02% +2) |
| Resistance | |
| Range | 400, 4000Ω, 40kΩ |
| Resolution | 0.01, 0.1, 1Ω |
| Accuracy | ±(0.02% +8) / ±(0.05% +10) / ±(0.1% +40) |
| Frequency | |
| Range | 200, 2000Hz, 20, 100kHz |
| Resolution | 0.01, 0.1, 1, 10Hz |
| Accuracy | ±(0.01% +1) (±3 dgt.), 100kHz: ±5 dgt. |
| Pulse | |
| Range | 100Hz, 1, 10kHz |
| Resolution | 1 cyc |
| Accuracy | ±2 dgt. |
| Switch Quantity | |
| Range | 100Hz, 1, 10, 100kHz |
| Resolution | 0.01, 0.1, 1, 10Hz |
| Accuracy | ±2 dgt. |
| Type R and Type S | |
| Range | 32 to 3212.6°F (0 to 1767°C) |
| Resolution | 1°F/°C |
| Accuracy | 32 to 212°F (0 to 100°C): ±2.7°F (±1.5°C) |
| 212 to 3212.6°F (100 to 1767°C): ±2.16°F (±1.2°C) | |
| Type B | |
| Range | 1112 to 3308°F (600 to 1820°C) |
| Resolution | 1°F/°C |
| Accuracy | 1112 to 1472°F (600 to 800°C): ±2.7°F (±1.5°C) |
| 1472 to 3308°F (800 to 1820°C): ±1.98°F (±1.1°C) | |
| Type E | |
| Range | -328 to 1832°F (-200 to 1000°C) |
| Resolution | 0.1°F/°C |
| Accuracy | -328 to -148°F (-200 to -100°C): ±1.08°F (±0.6°C) |
| -148 to 1112°F (-100 to 600°C): ±0.9°F (±0.5°C) | |
| 1112 to 1832°F (600 to 1000°C): ±0.72°F (±0.4°C) | |
| Type K | |
| Range | -328 to 2501.6°F (-200 to 1372°C) |
| Resolution | 0.1°F/°C |
| Accuracy | -328 to -148°F (-200 to -100°C): ±1.08°F (±0.6°C) |
| -148 to 752°F (-100 to 400°C): ±0.9°F (±0.5°C) | |
| 752 to 2192°F (400 to 1200°C): ±1.26°F (±0.7°C) | |
| 2192 to 2501.6°F (1200 to 1372°C): ±1.62°F (±0.9°C) | |
| Type J | |
| Range | -328 to 2192°F (-200 to 1200°C) |
| Resolution | 0.1°F/°C |
| Accuracy | -200 to -148°F (-200 to -100°C): ±1.08°F (±0.6°C) |
| -148 to 1472°F (-100 to 800°C): ±0.9°F (±0.5°C) | |
| 1472 to 2192°F (800 to 1200°C): ±1.26°F (±0.7°C) | |
| Type T | |
| Range | -418 to 752°F (-250 to 400°C) |
| Resolution | 0.1°F/°C |
| Accuracy | ±1.08°F (±0.6°C) |
| Type L | |
| Range | -328 to 1652°F (-200 to 900°C) |
| Resolution | 0.1°F/°C |
| Accuracy | -328 to 32°F (-200 to 0°C): ±1.53°F (±0.85°C) |
| 32 to 1652°F (0 to 900°C): ±1.26°F (±0.7°C) | |
| Type U | |
| Range | -328 to 752°F (-200 to 400°C) |
| Resolution | 0.1°F/°C |
| Accuracy | -328 to 32°F (-200 to 0°C): ±1.98°F (±1.1°C) |
| 32 to 752°F (0 to 400°C): ±1.35°F (±0.75°C) | |
| Type XK | |
| Range | -328 to 1472°F (-200 to 800°C) |
| Resolution | 0.1°F/°C |
| Accuracy | -328 to -148°F (-200 to -100°C): ±0.9°F (±0.5°C |
| -148 to 1472°F (-100 to 800°C): ±1.08°F (±0.6°C) | |
| Type BP | |
| Range | 32 to 4532°F (0 to 2500°C) |
| Resolution | 0.1°F/°C |
| Accuracy | 32 to 1472°F (0 to 800°C): ±2.16°F (±1.2°C) |
| 1472 to 4532°F (800 to 2500°C): ±4.5°F (±2.5°C) | |
| Pt100-385 | |
| Range | -328 to 1472°F (-200 to 800°C) |
| Resolution | 0.1°F/°C |
| Accuracy | ±0.6°F (±0.33°C) |
| Pt100-392 | |
| Range | -328 to 1166°F (-200 to 630°C) |
| Resolution | 0.1°F/°C |
| Accuracy | ±0.54°F (±0.3°C) |
| Pt200-385 | |
| Range | -328 to 1166°F (-200 to 630°C) |
| Resolution | 0.1°F/°C |
| Accuracy | -328 to 482°F (-200 to 250°C): ±0.36°F (±0.2°C) |
| 482 to 1166°F (250 to 630°C): ±1.44°F (±0.8°C) |
| Pt100-JIS | |
| Range | -328 to 1166°F (-200 to 630°C) |
| Resolution | 0.1°F/°C |
| Accuracy | ±0.54°F (±0.3°C) |
| Pt500-385 | |
| Range | -328 to 1166°F (-200 to 630°C) |
| Resolution | 0.1°F/°C |
| Accuracy | -328 to 932°F (-200 to 500°C): ±0.54°F (±0.3°C) |
| 932 to 1166°F (500 to 630°C): ±0.72°F (±0.4°C) |
| Pt1000-385 | |
| Range | -328 to 1166°F (-200 to 630°C) |
| Resolution | 0.1°F/°C |
| Accuracy | ±0.36°F (±0.2°C) |
| Cu10 | |
| Range | -148 to 500°F (-100 to 260°C) |
| Resolution | 0.1°F/°C |
| Accuracy | ±3.24°F (±1.8°C) |
| Cu50 | |
| Range | -58 to 302°F (-50 to 150°C) |
| Resolution | 0.1°F/°C |
| Accuracy | ±0.9°F (±0.5°C) |
| Cu100 | |
| Range | -58 to 302°F (-50 to 150°C) |
| Resolution | 0.1°F/°C |
| Accuracy | ±0.45°F (±0.25°C) |
| Ni120 | |
| Range | -112 to 500°F (-80 to 260°C) |
| Resolution | 0.1°F/°C |
| Accuracy | ±0.36°F (±0.2°C) |
| Ramp Functions | |
| Source functions | Voltage, Current, Resistance, Frequency, Temperature |
| Ramps | Slow ramp, fast ramp, 25% step-ramp |
| Loop Power Function | |
| Voltage | 24V |
| Accuracy | 10% |
| Maximum current | 22mA, short circuit protected |
| Step Functions | |
| Source functions | Voltage, Current, Resistance, Frequency, Temperature |
| Steps | 25% of range, 100% of range |
| Display | 20,000 count TFT color LCD display |
| Kick Stand | Yes |
| Power Supply | 1.2V x 6 AA rechargeable batteries |
| Auto Shut-off | Yes |
| Low Battery Indicator | Yes |
| Replaceable Test Leads | Yes |
| Product Certifications | CE, RoHS |
| Operating Temperature | 14 to 131°F (-10 to 55°C) |
| Operating Humidity Range | ≤95% |
| Storage Temperature | -4 to 158°F (-20 to 70°C) |
| Max. Operating Altitude | 6561' (2000m) |
| Dimensions | 7.7 x 3.7 x 2.3" (195 x 95 x 58mm) |
| Weight | 650g (22.92oz) |
REED R5850 Multi-Function Process Calibrator: A high-precision source and measure instrument with a built-in 24V loop power supply.
Traceable Calibration Certificate: Official NIST-traceable documentation with full data and uncertainties for audit readiness.
Set of Professional Test Leads: High-quality leads for secure connection to transmitters and control loops.
Alligator Clips: Large-grip clips for hands-free testing of terminal blocks and bus bars.
Hard Carrying Case: A durable, impact-resistant protective case with custom-molded foam inserts.
Type K Thermocouple Wire Probe: A ready-to-use probe for direct temperature measurement and thermocouple channel verification.
USB Cable: Connects the calibrator to a PC for data transfer.
Power Adapter: Recharges the internal battery pack for continuous bench or field use.
Batteries: Six rechargeable AA batteries included for immediate deployment.
Datasheet for the R5850-NIST Multi-Function Calibrator
Manual for the R5850-NIST Multi-Function Calibrator