ISTCertified Precision for Field & Lab Temperature Calibration

The Reed Instruments R2900-NIST is a high-stability dry-well calibrator engineered to verify the accuracy of temperature sensors, thermometers, and RTDs. With a precision range of 33 to 300°C (91.4 to 572°F), it provides a controlled environment for rigorous equipment testing. This specific model includes a Traceable Calibration Certificate with full data and uncertainties, ensuring your facility remains compliant with ISO and safety audit requirements.

Key Technical Advantages

  • Multi-Probe Compatibility: Features a versatile insert that accepts five different probe diameters (1/8", 3/16", 1/4", 5/16", 3/8") for maximum utility.

  • Rapid Thermal Stabilization: Reach your desired set-point quickly with advanced microprocessor control and a high-stability heating element.

  • Accuracy You Can Trust: Delivers an accuracy of ±0.5°C at lower ranges, making it an ideal secondary standard for industrial and laboratory environments.

  • Portable & Rugged: Designed for field use with a durable chassis and an easy-to-read LED display that shows both target and actual temperatures.

Ideal Applications for the REED R2900-NIST

  • Industrial Manufacturing: Regularly verify thermocouples and RTDs used in plastic injection molding, furnace controls, and chemical processing.

  • Calibration Laboratories: Serve as a reliable heat source for verifying liquid-in-glass thermometers and digital temperature tools.

  • Food & Beverage Industry: Calibrate probes used in ovens, smokers, and pasteurization equipment to ensure food safety and process consistency.

  • HVAC/R Maintenance: Test equipment used to monitor high-temperature boilers, steam lines, and industrial heating systems.

  • Energy Audits: Verify the accuracy of tools used to measure thermal efficiency in commercial and industrial power plants.

Specifications
Temperature Range 91 to 572°F (33 to 300°C)
Accuracy ≤212°F (≤100°C): ±1.6°F (0.8°C)
212 to 392°F (100 to 200°C): ±3.2°F (1.6°C)
392 to 572°F (200 to 300°C): ±5.6°F (2.8°C)
Stability ≤212°F (≤100°C): ±0.2°F (0.1°C)
212 to 392°F (100 to 200°C): ±0.4°F (0.2°C)
392 to 572°F (200 to 300°C): ±0.8°F (0.4°C)
Resolution 0.1°F (0.1°C)
Heating Time Approx. 30 mins from 91 to 572°F (33 to 300°C)
Cooling Time Approx. 30 mins from 572 to 122°F (300 to 100°C)
Well Depth 3.54" (90 mm)
Aperture Diameter ⌀3.5 mm(2), ⌀4.2 mm, ⌀5 mm, ⌀6.8 mm
Display Dual LED
Power Supply 110 V AC, 2.5 A
Product Certifications CE
Operating Temperature 41 to 95°F (5 to 35°C)
Storage Temperature -4 to 140°F (-20 to 60°C)
Operating Humidity Range 15 to 80%
Dimensions 7.1 x 4.5 x 8.8" (180 x 114 x 233 mm)
Weight 6.6 lbs (3 kg)

 

Included
  • Traceable Calibration Certificate with full Data and Uncertainties
  • Power Cord
Resources

Datasheet for the REED R2900-NIST Dry Block Calibrator, 91 to 572°F (33 to 300°C)

Manual for the REED R2900-NIST Dry Block Calibrator, 91 to 572°F (33 to 300°C)

Description

ISTCertified Precision for Field & Lab Temperature Calibration

The Reed Instruments R2900-NIST is a high-stability dry-well calibrator engineered to verify the accuracy of temperature sensors, thermometers, and RTDs. With a precision range of 33 to 300°C (91.4 to 572°F), it provides a controlled environment for rigorous equipment testing. This specific model includes a Traceable Calibration Certificate with full data and uncertainties, ensuring your facility remains compliant with ISO and safety audit requirements.

Key Technical Advantages

  • Multi-Probe Compatibility: Features a versatile insert that accepts five different probe diameters (1/8", 3/16", 1/4", 5/16", 3/8") for maximum utility.

  • Rapid Thermal Stabilization: Reach your desired set-point quickly with advanced microprocessor control and a high-stability heating element.

  • Accuracy You Can Trust: Delivers an accuracy of ±0.5°C at lower ranges, making it an ideal secondary standard for industrial and laboratory environments.

  • Portable & Rugged: Designed for field use with a durable chassis and an easy-to-read LED display that shows both target and actual temperatures.

Ideal Applications for the REED R2900-NIST

  • Industrial Manufacturing: Regularly verify thermocouples and RTDs used in plastic injection molding, furnace controls, and chemical processing.

  • Calibration Laboratories: Serve as a reliable heat source for verifying liquid-in-glass thermometers and digital temperature tools.

  • Food & Beverage Industry: Calibrate probes used in ovens, smokers, and pasteurization equipment to ensure food safety and process consistency.

  • HVAC/R Maintenance: Test equipment used to monitor high-temperature boilers, steam lines, and industrial heating systems.

  • Energy Audits: Verify the accuracy of tools used to measure thermal efficiency in commercial and industrial power plants.

Specifications
Temperature Range 91 to 572°F (33 to 300°C)
Accuracy ≤212°F (≤100°C): ±1.6°F (0.8°C)
212 to 392°F (100 to 200°C): ±3.2°F (1.6°C)
392 to 572°F (200 to 300°C): ±5.6°F (2.8°C)
Stability ≤212°F (≤100°C): ±0.2°F (0.1°C)
212 to 392°F (100 to 200°C): ±0.4°F (0.2°C)
392 to 572°F (200 to 300°C): ±0.8°F (0.4°C)
Resolution 0.1°F (0.1°C)
Heating Time Approx. 30 mins from 91 to 572°F (33 to 300°C)
Cooling Time Approx. 30 mins from 572 to 122°F (300 to 100°C)
Well Depth 3.54" (90 mm)
Aperture Diameter ⌀3.5 mm(2), ⌀4.2 mm, ⌀5 mm, ⌀6.8 mm
Display Dual LED
Power Supply 110 V AC, 2.5 A
Product Certifications CE
Operating Temperature 41 to 95°F (5 to 35°C)
Storage Temperature -4 to 140°F (-20 to 60°C)
Operating Humidity Range 15 to 80%
Dimensions 7.1 x 4.5 x 8.8" (180 x 114 x 233 mm)
Weight 6.6 lbs (3 kg)

 

Included
  • Traceable Calibration Certificate with full Data and Uncertainties
  • Power Cord
Resources

Datasheet for the REED R2900-NIST Dry Block Calibrator, 91 to 572°F (33 to 300°C)

Manual for the REED R2900-NIST Dry Block Calibrator, 91 to 572°F (33 to 300°C)

Shipping

Free Shipping on all orders within the contiguous United States via standard ground service.

Need it faster? Expedited shipping options are available. Contact us for a quote.

For international orders, please contact us for shipping rates before placing your order.

For full details, see our Shipping Policy.

Why Buy From Us

Price Match Promise

We work hard to offer competitive pricing on every product in our store.

If you find a lower total price (including shipping and taxes) from another authorized U.S. retailer, send us a link and we'll do our best to work with you on pricing: Contact Us