The Reed Instruments R8085-KIT is a professional-grade solution designed to simplify the measurement and calculation of personal sound exposure.
This comprehensive kit provides technicians with two R8085 Noise Dosimeters, allowing for simultaneous employee monitoring or site-wide assessments. Engineered for compliance with OSHA, CCOHS, and ANSI standards, the R8085-KIT ensures your safety audits are backed by accurate, traceable data.
Dual-Dosimeter Efficiency: Includes two high-accuracy R8085 units to double your monitoring capacity in the field.
Integrated Field Calibration: The included R8090 Sound Level Calibrator allows you to verify sensor accuracy before and after testing, a critical step for legal and safety compliance.
Streamlined Data Analysis: Use the R8085-PC software and USB cable to download logs and generate detailed reports of 8-hour sound exposure (dose %) and sound pressure levels (dB).
Rugged Professional Protection: Every component is securely housed in the R8888 Hard Carrying Case, featuring a laser-etched custom foam interior for maximum tool organization and protection.
OSHA & CCOHS Compliance: Conduct mandatory personal noise exposure surveys to protect workers and avoid regulatory fines.
Construction & Industrial Sites: Monitor heavy machinery operators and high-decibel environments to ensure safe working conditions.
Hearing Conservation Programs: Use the dual-dosimeter setup to document noise levels for employee hearing health tracking.
Environmental Impact Studies: Record acoustic levels at site boundaries or traffic zones for environmental and code enforcement.
Safety & Industrial Hygiene: Provide industrial hygienists with reliable, loggable data for comprehensive workplace risk assessments.
REED R8085 Noise Dosimeter: A high-precision personal monitoring tool engineered to measure, record, and calculate cumulative sound exposure (%Dose) and peak decibel levels (dB).
REED R8090 Sound Level Calibrator: Generates a consistent, stable acoustic signal at precise frequencies to verify and adjust the accuracy of your dosimeters before and after field use.
REED R8888 Medium Hard Carrying Case: An industrial-grade, injection-molded protective shell featuring custom-cut foam to keep your precision instruments organized and shielded from impacts.
REED R8085-PC Software: A dedicated Windows-based interface for advanced data analysis, allowing you to transform raw logs into professional compliance reports and projects.
REED R8085-USB Cable: A reliable, high-speed data link designed for seamless transfer of recorded noise exposure data from the dosimeter to your PC workstation.
| Measurement Type | Sound Pressure Level: dB Personal Noise Exposure: %Dose |
| Measuring Range(s) | 35 to 130dB Low: 35 to 80dB High: 80 to 130dB Auto: 35 to 130dB Dose: 70 to 130dB |
| Dynamic Range | 50dB (in each range) |
| Accuracy | 31.5Hz ±3.0dB, 63Hz ±2.0dB, 125Hz ±1.5dB, 250Hz ±1.5dB, 500Hz ±1.5dB, 1kHz ±1.0dB, 2kHz ±2.0dB, 4kHz ±3.0dB, 8kHz ±5.0dB |
| Resolution | 0.1dB |
| Response Time | Approx. 1 sec |
| Frequency Range | 31.5Hz to 8kHz |
| Frequency Weighting | A, C |
| Time Weighting | Fast/Slow (125mS and 1s) |
| Microphone | 0.5" (12.7mm) electret condenser |
| Display | 4-digit LCD |
| Backlit Display | Yes |
| Data Hold | Yes |
| Min | Yes |
| Max | Yes |
| Alarm Indicators | Over (visual on-screen) |
| Data Logging Capabilities | Yes |
| Real-Time Clock and Date Stamp | Yes |
| Selectable Sampling Rate | Yes (1, 2, 5, 10, 30, 60, 120, 300, 600, 1800, 3600s) |
| Selectable Dose Measurement Rate | Yes (0, 1, 5, 10, 15, 30mins/1, 2, 4, 8, 10, 12, 24hrs) |
| Auto Shut-off | Yes (after 10 mins/off) |
| Tripod Mountable | Yes |
| Low Battery Indicator | Yes |
| Power Supply | 3 x AAA batteries |
| Output | Yes, RS-232/USB (optional) |
| PC Connectivity | USB Cable (R8085-USB, optional) |
| Software | PC Software (R8085-PC, optional) |
| Software OS Compatability | Windows XP/Vista/7/8/10 |
| Product Certifications | CE, IEC61252, ANSI S1.25 for Noise Dose and Sound Exposure Meters, IEC 61672 Class 2/ANSI S1.4 Type S for Sound Level Meters |
| Operating Temperature | 32 to 122°F (0 to 50°C) |
| Storage Temperature | 14 to 140°F (-10 to 60°C) |
| Operating Humidity Range | <85% |
| Dimensions | 4.2 x 2.3 x 1.0" (107 x 58 x 25mm) |
| Weight | 4.3oz (122g) |
| Output Sound Pressure | 2 levels (94dB and 114dB) |
| Accuracy | ±0.5dB |
| Output Frequency | 1000Hz ±4% |
| Power Supply | 9V Battery |
| Product Certifications | CE |
| Operating Temperature | 32 to 104°F (0 to 40°C) |
| Storage Temperature | -4 to 140°F (-20 to 60°C) |
| Operating Humidity Range | 0 to 80% |
| Dimensions | 4.7 x 2 x 1.7" (120 x 51 x 43 mm) |
| Weight | 4.6oz (130g) |
Ensure your workplace meets the highest safety standards with the Reed Instruments R8085 Noise Dosimeter Kit. This all-in-one package is specifically designed for professionals conducting 8-hour noise exposure studies. By combining high-accuracy measurement with an easy-to-use field calibrator, the R8085-KIT removes the guesswork from OSHA and CCOHS compliance.
Engineered for Professional Performance:
Capture Critical Data: Measure %Dose and sound pressure levels with a high accuracy of ±1.0dB.
Ready for the Field: The kit includes two dosimeters, a calibrator, and specialized reporting software, ensuring you have everything needed for a full day of testing.
Customizable Settings: Easily adjust criterion levels, exchange rates, and thresholds to meet specific local or industry regulations.
Built to Last: Protected by a heavy-duty, injection-molded case, your instruments are safe from the rigors of construction sites and industrial floors.
Precision is the foundation of any reliable noise survey. This instructional guide explores the essential process of calibrating your sound level meter to ensure peak performance and data integrity.
Using the Reed Instruments R8080 Sound Level Meter and the R8090 Sound Level Calibrator, we demonstrate how to perform a field verification that meets the rigorous standards required for professional acoustics and industrial hygiene.
Why Calibration is Critical:
Audit Readiness: Regular calibration is often a legal requirement for OSHA and CCOHS compliance.
Reliable Data: Environmental factors can cause sensor drift; calibration corrects these variations to maintain ±1.4dB (or better) accuracy.
Universal Workflow: While this video features the R8080 and R8090, the fundamental principles shown are applicable to most professional-grade sound measurement tools.
Datasheet for the REED R8085-KIT Noise Dosimeter Kit
Manual for the REED R8085-KIT Noise Dosimeter Kit
Datasheet for the REED R8090 Sound Level Calibrator
Manual for the REED R8090 Sound Level Calibrator