Reed Instruments R5850-NIST Multi-Function Process Calibrator
- ✓ Free Shipping US Wide
- ✓ Need Help? Call Us At (888) 913-3691
- ✓ Get The Best Price. Call Us
- ✓ 30 Day Returns
The REED Instruments R5850-NIST is a high-accuracy, handheld solution for the calibration and troubleshooting of process control instrumentation.
Designed for versatility, the R5850 can both source (simulate) and measure a wide range of signals, including DC voltage, DC current (mA), eight types of thermocouples, and two types of RTDs. With the included NIST-Traceable Calibration Certificate, this tool provides the documented measurement integrity required for chemical plants, water treatment facilities, and pharmaceutical manufacturing.
Comprehensive Source/Measure Capability: Eliminate the need for multiple tools by simulating and measuring 0-10V DC and 0-22mA DC signals in a single device.
Universal Temperature Calibration: Supports the most common industrial sensors, including J, K, T, E, R, S, B, and N-type thermocouples, as well as Pt100 and Cu50 RTDs.
Integrated 24V Loop Power: Power and test 2-wire loops simultaneously, making it an all-in-one solution for transmitter maintenance.
Documented Accuracy: Ships with a NIST-traceable certificate containing full data and uncertainties, ensuring compliance with ISO and regulatory safety standards.
Field-Ready Design: Features an easy-to-read backlit LCD, internal memory for storing calibration set-points, and a rugged housing built for industrial environments.
Industrial Transmitter Calibration: Verify and adjust 4-20mA pressure, flow, and level transmitters.
HVAC/R Control Systems: Test and simulate temperature sensors (RTDs/Thermocouples) for large-scale climate control.
PLC and DCS Troubleshooting: Inject known signals into control systems to verify programming logic and I/O performance.
Chemical & Water Treatment: Maintain precise sensor accuracy in environments where chemical dosing depends on exact measurements.
Pharmaceutical & Food Processing: Ensure thermal monitoring equipment meets strict FDA and health safety compliance through traceable calibration.
| DC Voltage | |
| Range | 50, 500mV, 30V (upper display), 50V (lower display) |
| Resolution | 0.001, 0.01, 1mV, 0.001V |
| Accuracy | 50mV: ±(0.02% +10) / 500mV: ±(0.02% +5) |
| 30V (upper display): ±(0.02% +2) / 50V (lower display): ±(0.02% +2) |
| DC Current | |
| Range | 20mA at 0 to 24mA |
| Resolution | 0.001mA |
| Accuracy | ±(0.02% +2) |
| Loop Current | |
| Range | 20mA (loop) at 0 to 24mA |
| Resolution | 0.001mA |
| Accuracy | ±(0.02% +2) |
| Resistance | |
| Range | 500, 5000Ω |
| Resolution | 0.01, 0.1Ω |
| Accuracy | ±(0.05% +10) |
| Frequency | |
| Range | 100Hz, 1, 10, 100kHz |
| Resolution | 0.01, 0.1, 1Hz |
| Accuracy | ±(0.01% +1) |
| Type R and Type S | |
| Range | 32 to 3212.6°F (0 to 1767°C) |
| Resolution | 1°F/°C |
| Accuracy | 32 to 932°F (0 to 500°C): ±3.24°F (±1.8°C) |
| 32 to 932°F (0 to 500°C): ±3.24°F (±1.8°C) |
| Type B | |
| Range | 1112 to 3308°F (600 to 1820°C) |
| Resolution | 1°F/°C |
| Accuracy | 1112 to 1472°F (600 to 800°C): ±3.96°F (±2.2°C) |
| 1472 to 1832°F (800 to 1000°C): ±3.24°F (±1.8°C) | |
| 1832 to 3308°F (1000 to 1820°C): ±2.52°F (±1.4°C) |
| Type E | |
| Range | -58 to 1832°F (-50 to 1000°C) |
| Resolution | 0.1°F/°C |
| Accuracy | -58 to 32°F (-50 to 0°C): ±1.62°F (±0.9°C) |
| 32 to 1832°F (0 to 1000°C): ±2.7°F (±1.5°C) |
| Type K | |
| Range | -148 to 2501.6°F (-100 to 1372°C) |
| Resolution | 0.1°F/°C |
| Accuracy | -148 to 32°F (-100 to 0°C): ±2.16°F (±1.2°C) |
| 32 to 2501.6°F (0 to 1372°C): ±1.44°F (±0.8°C) |
| Type J | |
| Range | -76 to 2192°F (-60 to 1200°C) |
| Resolution | 0.1°F/°C |
| Accuracy | -76 to 32°F (-60 to 0°C): ±1.8°F (±1°C) |
| 32 to 2192°F (0 to 1200°C): ±1.26°F (±0.7°C) |
| Type T | |
| Range | -148 to 752°F (-100 to 400°C) |
| Resolution | 0.1°F/°C |
| Accuracy | -148 to 32°F (-100 to 0°C): ±1.8°F (±1°C) |
| 32 to 752°F (0 to 400°C): ±1.26°F (±0.7°C) |
| Type N | |
| Range | -328 to 2372°F (-200 to 1300°C) |
| Resolution | 0.1°F/°C |
| Accuracy | -328 to -148°F (-200 to -100°C): ±1.8°F (±1°C) |
| -148 to 1652°F (-100 to 900°C): ±1.26°F (±0.7°C) | |
| 1652 to 2372°F (900 to 1300°C): ±1.44°F (±0.8°C) |
| Type L | |
| Range | -328 to 1652°F (-200 to 900°C) |
| Resolution | 0.1°F/°C |
| Accuracy | -328 to 32°F (-200 to 0°C): ±1.53°F (±0.85°C) |
| 32 to 1652°F (0 to 900°C): ±1.26°F (±0.7°C) |
| Type U | |
| Range | 328 to 752°F (-200 to 400°C) |
| Resolution | 0.1°F/°C |
| Accuracy | -328 to 32°F (-200 to 0°C): ±1.98°F (±1.1°C) |
| 32 to 752°F (0 to 400°C): ±1.35°F (±0.75°C) |
| Type XK | |
| Range | -328 to 1472°F (-200 to 800°C) |
| Resolution | 0.1°F/°C |
| Accuracy | -328 to -148°F (-200 to -100°C): ±0.9°F (±0.5°C) |
| -148 to 1472°F (-100 to 800°C): ±1.08°F (±0.6°C) |
| Type BP | |
| Range | 32 to 4532°F (0 to 2500°C) |
| Resolution | 0.1°F/°C |
| Accuracy | 32 to 1472°F (0 to 800°C): ±2.16°F (±1.2°C) |
| 1472 to 4532°F (800 to 2500°C): ±4.5°F (±2.5°C) |
| Pt100 (2-wire/3-wire) | |
| Range | -328 to 1562°F (-200 to 850°C) |
| Resolution | 0.1°F/°C |
| Accuracy | ±0.72°F (±0.4°C) |
| Pt100 (4-wire) | |
| Range | -328 to 1562°F (-200 to 850°C) |
| Resolution | 0.1°F/°C |
| Accuracy | ±0.54°F (±0.3°C) |
| Pt200 (2-wire/3-wire) | |
| Range | -328 to 1166°F (-200 to 630°C) |
| Resolution | 0.1°F/°C |
| Accuracy | -328 to 482°F (-200 to 250°C): ±0.54°F (±0.3°C) |
| 482 to 1166°F (250 to 630°C): ±2.88°F (±1.6°C) |
| Pt200 (4-wire) | |
| Range | -328 to 1166°F (-200 to 630°C) |
| Resolution | 0.1°F/°C |
| Accuracy | -328 to 482°F (-200 to 250°C): ±0.36°F (±0.2°C) |
| 482 to 1166°F (250 to 630°C): ±1.44°F (±0.8°C) | |
| Pt500 (2-wire/3-wire) | |
| Range | -328 to 1166°F (-200 to 630°C) |
| Resolution | 0.1°F/°C |
| Accuracy | -328 to 932°F (-200 to 500°C): ±1.08°F (±0.6°C) |
| 932 to 1166°F (500 to 630°C): ±1.62°F (±0.9°C) | |
| Pt500 (4-wire) | |
| Range | -328 to 1166°F (-200 to 630°C) |
| Resolution | 0.1°F/°C |
| Accuracy | -328 to 932°F (-200 to 500°C): ±0.54°F (±0.3°C) |
| 932 to 1166°F (500 to 630°C): ±0.72°F (±0.4°C) |
| Pt1000 (2-wire/3-wire) | |
| Range | -328 to 1202°F (-200 to 650°C) |
| Resolution | 0.1°F/°C |
| Accuracy | ±0.54°F (±0.3°C) |
| Pt1000 (4-wire) | |
| Range | -328 to 1202°F (-200 to 650°C) |
| Resolution | 0.1°F/°C |
| Accuracy | ±0.27°F (±0.15°C) |
| Cu10 | |
| Range | -148 to 500°F (-100 to 260°C) |
| Resolution | 0.1°F/°C |
| Accuracy | ±3.24°F (±1.8°C) |
| Cu50 (2-wire/3-wire) | |
| Range | -58 to 302°F (-50 to 150°C) |
| Resolution | 0.1°F/°C |
| Accuracy | ±1.44°F (±0.8°C) |
| Cu50 (4-wire) | |
| Range | -58 to 302°F (-50 to 150°C) |
| Resolution | 0.1°F/°C |
| Accuracy | ±0.9°F (±0.5°C) |
| Cu100 (2-wire/3-wire) | |
| Range | -58 to 302°F (-50 to 150°C) |
| Resolution | 0.1°F/°C |
| Accuracy | ±0.72°F (±0.4°C) |
| Cu100 (4-wire) | |
| Range | -58 to 302°F (-50 to 150°C) |
| Resolution | 0.1°F/°C |
| Accuracy | ±0.45°F (±0.25°C) |
| Pt100-392 (2-wire/3-wire) | |
| Range | -328 to 1166°F (-200 to 630°C) |
| Resolution | 0.1°F/°C |
| Accuracy | ±0.9°F (±0.5°C) |
| Pt100-392 (4-wire) | |
| Range | -328 to 1166°F (-200 to 630°C) |
| Resolution | 0.1°F/°C |
| Accuracy | ±0.54°F (±0.3°C) |
| Pt100-JIS (2-wire/3-wire) | |
| Range | -328 to 1166°F (-200 to 630°C) |
| Resolution | 0.1°F/°C |
| Accuracy | ±0.9°F (±0.5°C) |
| Pt100-JIS (4-wire) | |
| Range | -328 to 1166°F (-200 to 630°C) |
| Resolution | 0.1°F/°C |
| Accuracy | ±0.54°F (±0.3°C) |
| Ni120 (2-wire/3-wire) | |
| Range | -112 to 500°F (-80 to 260°C) |
| Resolution | 0.1°F/°C |
| Accuracy | ±0.54°F (±0.3°C) |
| Ni120 (4-wire) | |
| Range | -112 to 500°F (-80 to 260°C) |
| Resolution | 0.1°F/°C |
| Accuracy | ±0.36°F (±0.2°C) |
| DC Voltage | |
| Range | 100mV, 1, 10V |
| Resolution | 0.001, 0.01mV, 0.0001V |
| Accuracy | ±(0.02% +10) |
| DC Current | |
| Range | 20mA at 0 to 24mA / 20mA (SIM) at 0 to 24mA |
| Resolution | 0.001mA |
| Accuracy | ±(0.02% +2) |
| Resistance | |
| Range | 400, 4000Ω, 40kΩ |
| Resolution | 0.01, 0.1, 1Ω |
| Accuracy | ±(0.02% +8) / ±(0.05% +10) / ±(0.1% +40) |
| Frequency | |
| Range | 200, 2000Hz, 20, 100kHz |
| Resolution | 0.01, 0.1, 1, 10Hz |
| Accuracy | ±(0.01% +1) (±3 dgt.), 100kHz: ±5 dgt. |
| Pulse | |
| Range | 100Hz, 1, 10kHz |
| Resolution | 1 cyc |
| Accuracy | ±2 dgt. |
| Switch Quantity | |
| Range | 100Hz, 1, 10, 100kHz |
| Resolution | 0.01, 0.1, 1, 10Hz |
| Accuracy | ±2 dgt. |
| Type R and Type S | |
| Range | 32 to 3212.6°F (0 to 1767°C) |
| Resolution | 1°F/°C |
| Accuracy | 32 to 212°F (0 to 100°C): ±2.7°F (±1.5°C) |
| 212 to 3212.6°F (100 to 1767°C): ±2.16°F (±1.2°C) | |
| Type B | |
| Range | 1112 to 3308°F (600 to 1820°C) |
| Resolution | 1°F/°C |
| Accuracy | 1112 to 1472°F (600 to 800°C): ±2.7°F (±1.5°C) |
| 1472 to 3308°F (800 to 1820°C): ±1.98°F (±1.1°C) | |
| Type E | |
| Range | -328 to 1832°F (-200 to 1000°C) |
| Resolution | 0.1°F/°C |
| Accuracy | -328 to -148°F (-200 to -100°C): ±1.08°F (±0.6°C) |
| -148 to 1112°F (-100 to 600°C): ±0.9°F (±0.5°C) | |
| 1112 to 1832°F (600 to 1000°C): ±0.72°F (±0.4°C) | |
| Type K | |
| Range | -328 to 2501.6°F (-200 to 1372°C) |
| Resolution | 0.1°F/°C |
| Accuracy | -328 to -148°F (-200 to -100°C): ±1.08°F (±0.6°C) |
| -148 to 752°F (-100 to 400°C): ±0.9°F (±0.5°C) | |
| 752 to 2192°F (400 to 1200°C): ±1.26°F (±0.7°C) | |
| 2192 to 2501.6°F (1200 to 1372°C): ±1.62°F (±0.9°C) | |
| Type J | |
| Range | -328 to 2192°F (-200 to 1200°C) |
| Resolution | 0.1°F/°C |
| Accuracy | -200 to -148°F (-200 to -100°C): ±1.08°F (±0.6°C) |
| -148 to 1472°F (-100 to 800°C): ±0.9°F (±0.5°C) | |
| 1472 to 2192°F (800 to 1200°C): ±1.26°F (±0.7°C) | |
| Type T | |
| Range | -418 to 752°F (-250 to 400°C) |
| Resolution | 0.1°F/°C |
| Accuracy | ±1.08°F (±0.6°C) |
| Type L | |
| Range | -328 to 1652°F (-200 to 900°C) |
| Resolution | 0.1°F/°C |
| Accuracy | -328 to 32°F (-200 to 0°C): ±1.53°F (±0.85°C) |
| 32 to 1652°F (0 to 900°C): ±1.26°F (±0.7°C) | |
| Type U | |
| Range | -328 to 752°F (-200 to 400°C) |
| Resolution | 0.1°F/°C |
| Accuracy | -328 to 32°F (-200 to 0°C): ±1.98°F (±1.1°C) |
| 32 to 752°F (0 to 400°C): ±1.35°F (±0.75°C) | |
| Type XK | |
| Range | -328 to 1472°F (-200 to 800°C) |
| Resolution | 0.1°F/°C |
| Accuracy | -328 to -148°F (-200 to -100°C): ±0.9°F (±0.5°C |
| -148 to 1472°F (-100 to 800°C): ±1.08°F (±0.6°C) | |
| Type BP | |
| Range | 32 to 4532°F (0 to 2500°C) |
| Resolution | 0.1°F/°C |
| Accuracy | 32 to 1472°F (0 to 800°C): ±2.16°F (±1.2°C) |
| 1472 to 4532°F (800 to 2500°C): ±4.5°F (±2.5°C) | |
| Pt100-385 | |
| Range | -328 to 1472°F (-200 to 800°C) |
| Resolution | 0.1°F/°C |
| Accuracy | ±0.6°F (±0.33°C) |
| Pt100-392 | |
| Range | -328 to 1166°F (-200 to 630°C) |
| Resolution | 0.1°F/°C |
| Accuracy | ±0.54°F (±0.3°C) |
| Pt200-385 | |
| Range | -328 to 1166°F (-200 to 630°C) |
| Resolution | 0.1°F/°C |
| Accuracy | -328 to 482°F (-200 to 250°C): ±0.36°F (±0.2°C) |
| 482 to 1166°F (250 to 630°C): ±1.44°F (±0.8°C) |
| Pt200 (4-wire) | |
| Range | -328 to 1166°F (-200 to 630°C) |
| Resolution | 0.1°F/°C |
| Accuracy | -328 to 482°F (-200 to 250°C): ±0.36°F (±0.2°C) |
| 482 to 1166°F (250 to 630°C): ±1.44°F (±0.8°C) | |
| Pt100-JIS | |
| Range | -328 to 1166°F (-200 to 630°C) |
| Resolution | 0.1°F/°C |
| Accuracy | ±0.54°F (±0.3°C) |
| Pt500-385 | |
| Range | -328 to 1166°F (-200 to 630°C) |
| Resolution | 0.1°F/°C |
| Accuracy | -328 to 932°F (-200 to 500°C): ±0.54°F (±0.3°C) |
| 932 to 1166°F (500 to 630°C): ±0.72°F (±0.4°C) |
| Pt1000-385 | |
| Range | -328 to 1166°F (-200 to 630°C) |
| Resolution | 0.1°F/°C |
| Accuracy | ±3.24°F (±1.8°C) |
| Cu10 | |
| Range | -148 to 500°F (-100 to 260°C) |
| Resolution | 0.1°F/°C |
| Accuracy | ±3.24°F (±1.8°C) |
| Cu50 | |
| Range | -58 to 302°F (-50 to 150°C) |
| Resolution | 0.1°F/°C |
| Accuracy | ±0.9°F (±0.5°C) |
| Cu100 | |
| Range | -58 to 302°F (-50 to 150°C) |
| Resolution | 0.1°F/°C |
| Accuracy | ±0.45°F (±0.25°C) |
| Ni120 | |
| Range | -112 to 500°F (-80 to 260°C) |
| Resolution | 0.1°F/°C |
| Accuracy | ±0.36°F (±0.2°C) |
| Ramp Functions | |
| Source functions | Voltage, Current, Resistance, Frequency, Temperature |
| Ramps | Slow ramp, fast ramp, 25% step-ramp |
| Loop Power Function | |
| Voltage | 24V |
| Accuracy | 10% |
| Maximum current | 22mA, short circuit protected |
| Step Functions | |
| Source functions | Voltage, Current, Resistance, Frequency, Temperature |
| Steps | 25% of range, 100% of range |
| Display | 20,000 count TFT color LCD display |
| Kick Stand | Yes |
| Power Supply | 1.2V x 6 AA rechargeable batteries |
| Auto Shut-off | Yes |
| Low Battery Indicator | Yes |
| Replaceable Test Leads | Yes |
| Product Certifications | CE, RoHS |
| Operating Temperature | 14 to 131°F (-10 to 55°C) |
| Operating Humidity Range | ≤95% |
| Storage Temperature | -4 to 158°F (-20 to 70°C) |
| Max. Operating Altitude | 6561' (2000m) |
| Dimensions | 7.7 x 3.7 x 2.3" (195 x 95 x 58mm) |
| Weight | 650g (22.92oz) |
REED R5850 Multi-Function Process Calibrator: A high-precision source and measure instrument with a built-in 24V loop power supply.
Traceable Calibration Certificate: Official NIST-traceable documentation with full data and uncertainties for audit readiness.
Set of Professional Test Leads: High-quality leads for secure connection to transmitters and control loops.
Alligator Clips: Large-grip clips for hands-free testing of terminal blocks and bus bars.
Hard Carrying Case: A durable, impact-resistant protective case with custom-molded foam inserts.
Batteries: Standard power cells included for immediate deployment.
Datasheet for the R5850-NIST Multi-Function Calibrator
Manual for the R5850-NIST Multi-Function Calibrator