{"product_id":"reed-instruments-r2900-dry-block-calibrator-nist","title":"Reed Instruments R2900 Dry Block Calibrator with NIST","description":"\u003ch2\u003e\n\u003cmeta charset=\"utf-8\"\u003e\n\u003cmeta charset=\"utf-8\"\u003eISTCertified Precision for Field \u0026amp; Lab Temperature Calibration\u003c\/h2\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eThe Reed Instruments \u003c\/span\u003e\u003cstrong\u003eR2900-NIST\u003c\/strong\u003e\u003cspan\u003e is a high-stability dry-well calibrator engineered to verify the accuracy of temperature sensors, thermometers, and RTDs. With a precision range of 33 to 300°C (91.4 to 572°F), it provides a controlled environment for rigorous equipment testing. This specific model \u003cstrong\u003eincludes a Traceable Calibration Certificate\u003c\/strong\u003e with full data and uncertainties, ensuring your facility remains compliant with ISO and safety audit requirements.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2 dir=\"ltr\"\u003e\u003cspan\u003eKey Technical Advantages\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\n\u003cp dir=\"ltr\" role=\"presentation\"\u003e\u003cspan\u003e\u003cstrong\u003eMulti-Probe Compatibility:\u003c\/strong\u003e \u003c\/span\u003e\u003cspan\u003eFeatures a versatile insert that accepts five different probe diameters (1\/8\", 3\/16\", 1\/4\", 5\/16\", 3\/8\") for maximum utility.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\n\u003cp dir=\"ltr\" role=\"presentation\"\u003e\u003cstrong\u003eRapid Thermal Stabilization: \u003c\/strong\u003e\u003cspan\u003eReach your desired set-point quickly with advanced microprocessor control and a high-stability heating element.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\n\u003cp dir=\"ltr\" role=\"presentation\"\u003e\u003cstrong\u003eAccuracy You Can Trust:\u003c\/strong\u003e\u003cspan\u003e Delivers an accuracy of ±0.5°C at lower ranges, making it an ideal secondary standard for industrial and laboratory environments.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\n\u003cp dir=\"ltr\" role=\"presentation\"\u003e\u003cstrong\u003ePortable \u0026amp; Rugged:\u003c\/strong\u003e\u003cspan\u003e Designed for field use with a durable chassis and an easy-to-read LED display that shows both target and actual temperatures.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eIdeal Applications for the REED R2900-NIST\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\n\u003cp dir=\"ltr\" role=\"presentation\"\u003e\u003cstrong\u003eIndustrial Manufacturing: \u003c\/strong\u003e\u003cspan\u003eRegularly verify thermocouples and RTDs used in plastic injection molding, furnace controls, and chemical processing.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\n\u003cp dir=\"ltr\" role=\"presentation\"\u003e\u003cstrong\u003eCalibration Laboratories:\u003c\/strong\u003e\u003cspan\u003e Serve as a reliable heat source for verifying liquid-in-glass thermometers and digital temperature tools.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\n\u003cp dir=\"ltr\" role=\"presentation\"\u003e\u003cstrong\u003eFood \u0026amp; Beverage Industry:\u003c\/strong\u003e\u003cspan\u003e Calibrate probes used in ovens, smokers, and pasteurization equipment to ensure food safety and process consistency.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\n\u003cp dir=\"ltr\" role=\"presentation\"\u003e\u003cstrong\u003eHVAC\/R Maintenance:\u003c\/strong\u003e\u003cspan\u003e\u003cstrong\u003e \u003c\/strong\u003eTest equipment used to monitor high-temperature boilers, steam lines, and industrial heating systems.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\n\u003cp dir=\"ltr\" role=\"presentation\"\u003e\u003cspan\u003e\u003c\/span\u003e\u003cmeta charset=\"utf-8\"\u003e\u003cmeta charset=\"utf-8\"\u003e\u003cb id=\"docs-internal-guid-00755966-7fff-e7ca-75c8-3227d1dadb39\"\u003e\u003cspan\u003eEnergy Audits:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003eVerify the accuracy of tools used to measure thermal efficiency in commercial and industrial power plants.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eSpecifications\u003c\/h5\u003e\n\u003ctable class=\"table table-striped\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Range\u003c\/td\u003e\n\u003ctd\u003e91 to 572°F (33 to 300°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e≤212°F (≤100°C): ±1.6°F (0.8°C)\u003cbr\u003e212 to 392°F (100 to 200°C): ±3.2°F (1.6°C)\u003cbr\u003e392 to 572°F (200 to 300°C): ±5.6°F (2.8°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStability\u003c\/td\u003e\n\u003ctd\u003e≤212°F (≤100°C): ±0.2°F (0.1°C)\u003cbr\u003e212 to 392°F (100 to 200°C): ±0.4°F (0.2°C)\u003cbr\u003e392 to 572°F (200 to 300°C): ±0.8°F (0.4°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1°F (0.1°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Time\u003c\/td\u003e\n\u003ctd\u003eApprox. 30 mins from 91 to 572°F (33 to 300°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling Time\u003c\/td\u003e\n\u003ctd\u003eApprox. 30 mins from 572 to 122°F (300 to 100°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWell Depth\u003c\/td\u003e\n\u003ctd\u003e3.54\" (90 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAperture Diameter\u003c\/td\u003e\n\u003ctd\u003e⌀3.5 mm(2), ⌀4.2 mm, ⌀5 mm, ⌀6.8 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003eDual LED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e110 V AC, 2.5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Certifications\u003c\/td\u003e\n\u003ctd\u003eCE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e41 to 95°F (5 to 35°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-4 to 140°F (-20 to 60°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Humidity Range\u003c\/td\u003e\n\u003ctd\u003e15 to 80%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e7.1 x 4.5 x 8.8\" (180 x 114 x 233 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e6.6 lbs (3 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eIncluded\u003cbr\u003e\u003cmeta charset=\"utf-8\"\u003e\n\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003eTraceable Calibration Certificate with full Data and Uncertainties\u003c\/li\u003e\n\u003cli\u003ePower Cord\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eResources\u003c\/h5\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0709\/8558\/0712\/files\/Reed_R2900_datasheet.pdf?v=1762384158\" title=\"Reed R2900 datasheet\" rel=\"noopener\" target=\"_blank\"\u003e\u003cspan class=\"main-color\"\u003e\u003cstrong\u003eDatasheet\u003c\/strong\u003e\u003c\/span\u003e\u003c\/a\u003e\u003cspan\u003e \u003c\/span\u003efor the \u003cstrong\u003eREED R2900-NIST\u003c\/strong\u003e Dry Block Calibrator, 91 to 572°F (33 to 300°C)\u003c\/p\u003e\n\u003cp\u003e\u003ca rel=\"noopener\" title=\"Reed R2900 manual\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0709\/8558\/0712\/files\/Reed_R2900_manual.pdf?v=1762384159\" target=\"_blank\"\u003e\u003cspan class=\"main-color\"\u003e\u003cstrong\u003eManual\u003c\/strong\u003e\u003c\/span\u003e\u003c\/a\u003e\u003cspan\u003e \u003c\/span\u003efor the \u003cstrong\u003eREED R2900-NIST\u003c\/strong\u003e Dry Block Calibrator, 91 to 572°F (33 to 300°C)\u003c\/p\u003e","brand":"Reed Instruments","offers":[{"title":"Default Title","offer_id":54370837659816,"sku":null,"price":2045.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0709\/8558\/0712\/files\/Reed_Instruments_R2900_Dry_Block_Calibrator.jpg?v=1762204013","url":"https:\/\/westerlyapollo.com\/products\/reed-instruments-r2900-dry-block-calibrator-nist","provider":"Westerly Apollo","version":"1.0","type":"link"}