{"product_id":"power-analyzer-pce-pa-8300-2","title":"PCE-PA 8300-2 Three-Phase Power Analyzer","description":"\u003ch2\u003eThree-Phase Power Analyzer \u003cstrong\u003ePCE-PA 8300-2\u003c\/strong\u003e – Portable Power Meter, Data Logger \u0026amp; Clamp-On Tester with Three Flexible Rogowski Coils up to 3,000 A\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003ePCE-PA 8300-2\u003c\/strong\u003e is a portable three-phase power analyzer, power data logger, and clamp-on tester for electricians, maintenance engineers, and facility managers who document power quality on industrial and commercial installations. It measures 10 V to 600 V AC, active, apparent, and reactive power up to 9.999 MW, energy, power factor, phase angle, frequency, and harmonics up to the 50th order. \u003cstrong\u003eThis model includes three flexible Rogowski coil current sensors with 30 \/ 300 \/ 3,000 A AC ranges\u003c\/strong\u003e that wrap around large, awkward, or tightly packed conductors and busbars where rigid clamp jaws cannot reach.\u003c\/p\u003e\n\u003ch3\u003eWhich Model Do You Need?\u003c\/h3\u003e\n\u003cp\u003eThe PCE-PA 8300 analyzer is sold in two configurations that differ only in the current sensors supplied. The \u003cstrong\u003ePCE-PA 8300-2\u003c\/strong\u003e on this page includes \u003cstrong\u003ethree flexible Rogowski coils for measurements up to 3,000 A\u003c\/strong\u003e – the right choice for busbars, cable bundles, and cramped panels. If you measure standard cables and conductors up to 1,200 A, the \u003ca href=\"\/products\/power-analyzer-pce-pa-8300-1\"\u003e\u003cstrong\u003ePCE-PA 8300-1\u003c\/strong\u003e with three rigid current clamps\u003c\/a\u003e covers that at a lower price. The base instrument and every other specification are identical.\u003c\/p\u003e\n\u003ch3\u003ePower, Energy \u0026amp; Harmonics Analysis\u003c\/h3\u003e\n\u003cp\u003eOn its 3.7 in (94 mm) graphic display, the \u003cstrong\u003ePCE-PA 8300-2\u003c\/strong\u003e shows waveform and harmonic content simultaneously and plots a live phasor diagram of all three phases. The analyzer measures active, apparent, and reactive power to 9.999 MW (MVA \/ MVAR), active and apparent energy, power factor from 0 to 1, phase (delay) angle from -180° to +180°, and line frequency from 45 Hz to 65 Hz. Harmonic spectrum measurement extends to the 50th order, and the instrument captures transients including dips, swells, and outages – the data needed for power quality troubleshooting and network capacity checks.\u003c\/p\u003e\n\u003ch3\u003eLong-Term Data Logging on SD Card\u003c\/h3\u003e\n\u003cp\u003eAs a three-phase power data logger, the \u003cstrong\u003ePCE-PA 8300-2\u003c\/strong\u003e records measurements directly to SD card in real time. Set a record interval anywhere from 2 to 7,200 seconds, press record, and leave the analyzer to document a machine, feeder, or complete installation over hours or weeks. Afterwards, open the logged files on a PC to analyze consumption, harmonics, or transient events; a USB or RS232 connection also supports live display on a computer.\u003c\/p\u003e\n\u003ch3\u003eBuilt for the Field\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003ePCE-PA 8300-2\u003c\/strong\u003e carries an IEC1010 CAT III 600 V safety rating and is housed in a durable enclosure measuring 225 x 125 x 64 mm (8.8 x 4.9 x 2.5 in) and weighing 948 g (33.4 oz) including batteries. Power comes from eight 1.5 V AA batteries or the included 9 V mains adapter, supporting both quick spot checks and long-term monitoring. The current inputs are also compatible with power clamps from various other manufacturers.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThree flexible Rogowski coils included, with measurement ranges of 30 \/ 300 \/ 3,000 A AC\u003c\/li\u003e\n\u003cli\u003eVoltage measurement range of 10 V ... 600 V AC with auto-ranging\u003c\/li\u003e\n\u003cli\u003eActive, apparent, and reactive power measurement from 0 kW ... 9.999 MW (VA \/ VAR)\u003c\/li\u003e\n\u003cli\u003eHarmonic spectrum measurement up to the 50th order\u003c\/li\u003e\n\u003cli\u003eSimultaneous display of harmonics and waveform, plus graphic phasor diagram\u003c\/li\u003e\n\u003cli\u003eCaptures transients including dip, swell, and outage\u003c\/li\u003e\n\u003cli\u003eLong-term data logging to SD card with adjustable record interval of 2 ... 7,200 seconds\u003c\/li\u003e\n\u003cli\u003e3.7 in (94 mm) graphic LCD with LED backlight\u003c\/li\u003e\n\u003cli\u003eIEC1010 CAT III 600 V safety rating in a durable enclosure\u003c\/li\u003e\n\u003cli\u003eCompatible with power clamps from various manufacturers\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eSpecifications\u003c\/h5\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ch4\u003eVoltage Measurement (AC V)\u003c\/h4\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eMeasurement range\u003c\/th\u003e\n\u003cth\u003eResolution\u003c\/th\u003e\n\u003cth\u003eAccuracy\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e10 V ... 600 V (phase to neutral)\u003c\/td\u003e\n\u003ctd\u003e0.1 V\u003c\/td\u003e\n\u003ctd\u003e±(0.5 % + 0.5 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e10 V ... 600 V (phase to phase)\u003c\/td\u003e\n\u003ctd\u003e0.1 V\u003c\/td\u003e\n\u003ctd\u003e±(0.5 % + 0.5 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003eCurrent Measurement (AC A) – Flexible Rogowski Coils (included)\u003c\/h4\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eMeasurement range\u003c\/th\u003e\n\u003cth\u003eResolution\u003c\/th\u003e\n\u003cth\u003eAccuracy\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e30 A\u003c\/td\u003e\n\u003ctd\u003e0.001 A (\u0026lt; 10 A)\u003cbr\u003e0.01 A (≥ 10 A)\u003c\/td\u003e\n\u003ctd\u003e±(0.5 % + 0.1 A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e300 A\u003c\/td\u003e\n\u003ctd\u003e0.01 A (\u0026lt; 10 A)\u003cbr\u003e0.1 A (≥ 10 A)\u003c\/td\u003e\n\u003ctd\u003e±(0.5 % + 0.5 A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3000 A\u003c\/td\u003e\n\u003ctd\u003e0.1 A (\u0026lt; 1000 A)\u003cbr\u003e1 A (≥ 1000 A)\u003c\/td\u003e\n\u003ctd\u003e±(0.5 A + 5 A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003eEffective Power\u003c\/h4\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eMeasurement range\u003c\/th\u003e\n\u003cth\u003eResolution\u003c\/th\u003e\n\u003cth\u003eAccuracy\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e0 KW ... 9.999 KW\u003c\/td\u003e\n\u003ctd\u003e0.001 KW\u003c\/td\u003e\n\u003ctd\u003e±(1 % + 0.008 KW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e10 KW ... 99.99 KW\u003c\/td\u003e\n\u003ctd\u003e0.01 KW\u003c\/td\u003e\n\u003ctd\u003e±(1 % + 0.08 KW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e100 KW ... 999.9 KW\u003c\/td\u003e\n\u003ctd\u003e0.1 KW\u003c\/td\u003e\n\u003ctd\u003e±(1 % + 0.8 KW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1 MW ... 9.999 MW\u003c\/td\u003e\n\u003ctd\u003e0.001 MW\u003c\/td\u003e\n\u003ctd\u003e±(1 % + 0.008 MW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003eApparent Power\u003c\/h4\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eMeasurement range\u003c\/th\u003e\n\u003cth\u003eResolution\u003c\/th\u003e\n\u003cth\u003eAccuracy\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e0 KVA ... 9.999 KVA\u003c\/td\u003e\n\u003ctd\u003e0.001 KVA\u003c\/td\u003e\n\u003ctd\u003e±(1 % + 0.008 KVA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e10 KVA ... 99.99 KVA\u003c\/td\u003e\n\u003ctd\u003e0.01 KVA\u003c\/td\u003e\n\u003ctd\u003e±(1 % + 0.08 KVA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e100 KVA ... 999.9 KVA\u003c\/td\u003e\n\u003ctd\u003e0.1 KVA\u003c\/td\u003e\n\u003ctd\u003e±(1 % + 0.8 KVA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1 MVA ... 9.999 MVA\u003c\/td\u003e\n\u003ctd\u003e0.001 MVA\u003c\/td\u003e\n\u003ctd\u003e±(1 % + 0.008 MVA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003eReactive Power\u003c\/h4\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eMeasurement range\u003c\/th\u003e\n\u003cth\u003eResolution\u003c\/th\u003e\n\u003cth\u003eAccuracy\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e0 KVAR ... 9.999 KVAR\u003c\/td\u003e\n\u003ctd\u003e0.001 KVAR\u003c\/td\u003e\n\u003ctd\u003e±(1 % + 0.008 KVAR)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e10 KVAR ... 99.99 KVAR\u003c\/td\u003e\n\u003ctd\u003e0.01 KVAR\u003c\/td\u003e\n\u003ctd\u003e±(1 % + 0.08 KVAR)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e100 KVAR ... 999.9 KVAR\u003c\/td\u003e\n\u003ctd\u003e0.1 KVAR\u003c\/td\u003e\n\u003ctd\u003e±(1 % + 0.8 KVAR)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1 MVAR ... 9.999 MVAR\u003c\/td\u003e\n\u003ctd\u003e0.001 MVAR\u003c\/td\u003e\n\u003ctd\u003e±(1 % + 0.008 MVAR)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003eActive Energy\u003c\/h4\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eMeasurement range\u003c\/th\u003e\n\u003cth\u003eResolution\u003c\/th\u003e\n\u003cth\u003eAccuracy\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e0 KWH ... 9.999 KWH\u003c\/td\u003e\n\u003ctd\u003e0.001 KWh\u003c\/td\u003e\n\u003ctd\u003e±(2 % + 0.008 KWh)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e10.00 KWH ... 99.99 KWH\u003c\/td\u003e\n\u003ctd\u003e0.01 KWh\u003c\/td\u003e\n\u003ctd\u003e±(2 % + 0.08 KWh)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e100.0 KWH ... 999.9 KWH\u003c\/td\u003e\n\u003ctd\u003e0.01 KWh\u003c\/td\u003e\n\u003ctd\u003e±(2 % + 0.8 KWh)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1 MWH ... 9.999 MWH\u003c\/td\u003e\n\u003ctd\u003e0.001 MWh\u003c\/td\u003e\n\u003ctd\u003e±(2 % + 0.008 MWh)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003eApparent Energy\u003c\/h4\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eMeasurement range\u003c\/th\u003e\n\u003cth\u003eResolution\u003c\/th\u003e\n\u003cth\u003eAccuracy\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e0 KVARH ... 9.999 KVARH\u003c\/td\u003e\n\u003ctd\u003e0.001 KVARh\u003c\/td\u003e\n\u003ctd\u003e±(2 % + 0.008 KVARh)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e10.00 KVARH ... 99.99 KVARH\u003c\/td\u003e\n\u003ctd\u003e0.01 KVARh\u003c\/td\u003e\n\u003ctd\u003e±(2 % + 0.08 KVARh)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e100.0 KVARH ... 999.9 KVARH\u003c\/td\u003e\n\u003ctd\u003e0.01 KVARh\u003c\/td\u003e\n\u003ctd\u003e±(2 % + 0.8 KVARh)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1 MVARH ... 9.999 MVARH\u003c\/td\u003e\n\u003ctd\u003e0.001 MVARh\u003c\/td\u003e\n\u003ctd\u003e±(2 % + 0.008 MVARh)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003ePower Factor\u003c\/h4\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eMeasurement range\u003c\/th\u003e\n\u003cth\u003eResolution\u003c\/th\u003e\n\u003cth\u003eAccuracy\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e0 ... 1\u003c\/td\u003e\n\u003ctd\u003e0.01\u003c\/td\u003e\n\u003ctd\u003e±0.04\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003eDelay Angle\u003c\/h4\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eMeasurement range\u003c\/th\u003e\n\u003cth\u003eResolution\u003c\/th\u003e\n\u003cth\u003eAccuracy\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e-180° ... +180°\u003c\/td\u003e\n\u003ctd\u003e0.1°\u003c\/td\u003e\n\u003ctd\u003e±1°\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003eFrequency\u003c\/h4\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eMeasurement range\u003c\/th\u003e\n\u003cth\u003eResolution\u003c\/th\u003e\n\u003cth\u003eAccuracy\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e45 Hz ... 65 Hz\u003c\/td\u003e\n\u003ctd\u003e0.1 Hz\u003c\/td\u003e\n\u003ctd\u003e±0.1 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003eHarmonic of AC Voltage at 50 \/ 60 Hz\u003c\/h4\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eMeasurement range\u003c\/th\u003e\n\u003cth\u003eResolution\u003c\/th\u003e\n\u003cth\u003eAccuracy\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e1 ... 20th order\u003c\/td\u003e\n\u003ctd\u003e0.001 ... 1 A\u003cbr\u003e0.1 %\u003c\/td\u003e\n\u003ctd\u003e±(2 % + 0.5 A)\u003cbr\u003e±(2 % + 10 Digit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e21 ... 30th order\u003c\/td\u003e\n\u003ctd\u003e0.001 ... 1 A\u003cbr\u003e0.1 %\u003c\/td\u003e\n\u003ctd\u003e±(2 % + 0.5 A)\u003cbr\u003e±(2 % + 10 Digit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e21 ... 50th order\u003c\/td\u003e\n\u003ctd\u003e0.001 ... 1 A\u003cbr\u003e0.1 %\u003c\/td\u003e\n\u003ctd\u003enot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eGeneral Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003e3.7 in \/ 94.0 mm point-matrix LCD (320 x 240 pixel) with LED backlight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety standards\u003c\/td\u003e\n\u003ctd\u003eIEC1010 CAT III 600 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput resistance AC V\u003c\/td\u003e\n\u003ctd\u003e10 MOhm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating frequency of current clamp\u003c\/td\u003e\n\u003ctd\u003e40 Hz ... 1 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTested operating frequency of current clamp\u003c\/td\u003e\n\u003ctd\u003e45 Hz ... 65 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverload protection\u003c\/td\u003e\n\u003ctd\u003eAC V: 720 V RMS \/ AC A: 1300 A with current clamp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData storage\u003c\/td\u003e\n\u003ctd\u003eSD memory card\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefresh interval\u003c\/td\u003e\n\u003ctd\u003e1 second\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData logging function\u003c\/td\u003e\n\u003ctd\u003eLogging with real-time speed on SD memory card\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecord interval\u003c\/td\u003e\n\u003ctd\u003e2 ... 7200 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData output (only for live display on computer)\u003c\/td\u003e\n\u003ctd\u003ePer USB or RS232, depending on connection cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd\u003e0 °C ... +50 °C \/ 32 °F ... 122 °F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSurrounding humidity\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 80 % RH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower supply\u003c\/td\u003e\n\u003ctd\u003e8 x 1.5 V AA batteries \/ 9 V mains adapter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent drain\u003c\/td\u003e\n\u003ctd\u003eMeasurement device: 300 mA DC \/ Current clamp: 34 mA DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum wire diameter\u003c\/td\u003e\n\u003ctd\u003e50 mm \/ 1.9 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight (measurement device)\u003c\/td\u003e\n\u003ctd\u003e948 g \/ 33.4 oz (incl. battery)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight (current clamp)\u003c\/td\u003e\n\u003ctd\u003e467 g \/ 16.4 oz (incl. cable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (device)\u003c\/td\u003e\n\u003ctd\u003e225 mm x 125 mm x 64 mm \/ 8.8 in x 4.9 in x 2.5 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (current clamp)\u003c\/td\u003e\n\u003ctd\u003e210 mm x 64 mm x 33 mm \/ 8.2 in x 2.5 in x 1.2 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClamp jaw\u003c\/td\u003e\n\u003ctd\u003e86 mm \/ 3.3 in (exterior)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch5\u003eVideo\u003c\/h5\u003e\n\u003cp\u003e\u003ciframe title=\"YouTube video player\" src=\"https:\/\/www.youtube.com\/embed\/CTvQFQXPjio?si=QliLeaP1h2t_ZWYM\" height=\"315\" width=\"560\"\u003e\u003c\/iframe\u003e\u003c\/p\u003e\n\u003cp\u003eSee the \u003cstrong\u003ePCE-PA 8300\u003c\/strong\u003e series three-phase power analyzer in action.\u003c\/p\u003e\n\u003ch5\u003eIncluded\u003c\/h5\u003e\n\u003ch3\u003eIncluded in Delivery\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x \u003cstrong\u003ePCE-PA 8300\u003c\/strong\u003e three-phase power analyzer\u003c\/li\u003e\n\u003cli\u003e3 x Flexible Rogowski coils (measurements up to 3,000 A)\u003c\/li\u003e\n\u003cli\u003e4 x Insulated alligator clips\u003c\/li\u003e\n\u003cli\u003e4 x Safety test lines\u003c\/li\u003e\n\u003cli\u003e6 x 1.5 V AA batteries\u003c\/li\u003e\n\u003cli\u003e1 x 9 V mains adapter\u003c\/li\u003e\n\u003cli\u003e1 x SD memory card\u003c\/li\u003e\n\u003cli\u003e1 x Carrying case\u003c\/li\u003e\n\u003cli\u003e1 x User manual\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eResources\u003c\/h5\u003e\n\u003cp\u003e\u003cstrong\u003e\u003ca rel=\"noopener\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0709\/8558\/0712\/files\/Power-Analysator_PCE-PA_8300-2_-_Datasheet.pdf?v=1767849448\" target=\"_blank\"\u003eDatasheet\u003c\/a\u003e\u003c\/strong\u003e for the \u003cstrong\u003ePCE-PA 8300-2\u003c\/strong\u003e Power-Analysator\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003ca rel=\"noopener\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0709\/8558\/0712\/files\/Power-Analysator_PCE-PA_8300-2_-_Manual.pdf?v=1767849448\" target=\"_blank\"\u003eManual\u003c\/a\u003e\u003c\/strong\u003e for the \u003cstrong\u003ePCE-PA 8300-2\u003c\/strong\u003e Power-Analysator\u003c\/p\u003e","brand":"PCE INSTRUMENTS","offers":[{"title":"Default Title","offer_id":55129929384104,"sku":"PCE-PA 8300-2","price":4665.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0709\/8558\/0712\/files\/Power-AnalysatorPCE-PA8300-2.jpg?v=1767849352","url":"https:\/\/westerlyapollo.com\/products\/power-analyzer-pce-pa-8300-2","provider":"Westerly Apollo","version":"1.0","type":"link"}